Boilers

Boilers made by Proincar

Caldera recuperación
Caldera recuperación
Caldera recuperación

Boilers 1 & 2

  • Type: 2 Recovery Boilers
  • Disposition: Vertical (2 parts in each boilers)
  • Design Data: Boiler 1 + Boiler 2:
    • Design Pressure: 15 Kg/cm2 / Design Temperature: 330°C
  • Dimensions, Nº of Tubes, Material:

    • Boiler 1: 4535 x 2630(Part 1)+2890(Part 2) / 1040 Tubes (ø44,5 x 3,2) / Mat.: A-192
    • Boiler 2: 5970 x 2890(Part 1)+2790(Part 2) / 1248 Tubes (ø44,5 x 3,2) / Mat.: A-192
  • Fabrication Date: 2017
  • Client, Delivery Place: AITESA / CALBIYIK GRUP (Turkey)

Boiler 685-E-003

  • Type: Superheater
  • Disposition: Vertical
  • Design Data:
    • Superheater – Design Pressure: 48.5Kg/cm2 / Design Temperature: 521°C
    • Vaporizer – Design Pressure: 48Kg/cm2 / Design Temperature: 270°C
  • Dimensions, Nº de Tubes, Material:
    • Superheater: 3.600 x 2.190 / 672 Tubes (ø44.5 x 4mm.Thk.) / Mat.: A-213 T22
    • Vaporizer: 2.580 x 2.040 / 384 Tubes (ø44.5 x 4mm.Thk.) / Mat.: SA-106 Gr.B
  • Fabrication Date: 2015
  • Client, Delivery Place: Aitesa-Repsol / Cartagena Refinery, Region of Murcia (Spain)
calderas caldereria industrial
calderas caldereria industrial
calderas caldereria industrial
calderas caldereria industrial
calderas caldereria industrial
calderas caldereria industrial
calderas caldereria industrial
calderas caldereria industrial

Boiler 620-BL-1603-2

  • Type: Economizer + Vaporizer
  • Disposition: Vertical (2 modules)
  • Design Data:
    • Economizer + Vaporizer: Design pressure: 56.5Kg/cm2 / Design Temperature: 270°C
  • Dimensions, Nº de Tubes, Material:
    • Vaporizer: 8.280 x 2.190 / 1080 Tubes (ø51 x 4mm.Thk.) / Mat.: SA-192
    • Economizer: 3.000 x 2.500 / 616 Tubes (ø51 x 4mm.Thk.) / Mat.: SA-192
  • Fabrication Date: 2015
  • Client, Delivery Place: Aitesa-Repsol / A Coruña Refinery, Galicia (Spain)

Recovery Boiler. Zinc Nacional

  • Type: Heat Recovery Boiler / Cogeneration Unit
  • Arrangement: Vertical / 3 modules / HP Superheater Vaporizer / HP Economizer + LP Vaporizer + LP/HP Economizer
  • Design data:
    • Superheater: Design pressure: 48.2 Kg/cm2/ Design temperature: 540° C. HP Vaporiser: Design pressure: 49 Kg/cm2/ Design temperature: 300° C. HP
    • Economizer: Design pressure: 65Kg/cm2. Design temperature: 260° C. HP Vaporizer: Design pressure: 10.2 Kg/cm2 Design temperature: 120° C LP/HP
    • Economizer: Design pressure: 65Kg/cm2 Design temperature: 180°C
  • Nº of Tubes, Dimensions, Material:

    • Superheater: 288 (ø51 x 4mm.Thk.) Mat.: A-192 / Vaporizer A.P.: 96(ø51 x 4mm.Thk.) Mat.: A-192 / Economizer B.P/A.P..: 216(ø25,4 x 2,4mm.Thk.) Mat.: A-192
  • Date of manufacture: 2014
  • Customer, Installed at: Aitesa / Zinc Nacional (Mexico City)
calderas caldereria industrial
calderas caldereria industrial
calderas caldereria industrial
calderas caldereria industrial

4 Superheater. Prayon

  • Type: Superheater
  • Arrangement: Horizontal
  • Design data:
    • Superheater: Design pressure: 62 Kg/cm2 / Design temperature: 550° C
  • Nº of Tubes, Dimensions, Material:
    • Superheater(ea.): 360 Tubes (ø51 x 4 mm thk.) / Mat.: A-335 Gr. P91
  • Date of manufacture: 2013
  • Customer, Installed at:
    AIT France / Gabes (Belgium)

Recovery Boiler. OCP SAFI

  • Type: Economizer + Superheater
  • Arrangement: Vertical (2 modules)
  • Desig data:
    • Economiser + Superheater: Design pressure: 72Kg/cm2 / Design temperature: 315°C
  • Dimensions, Nº of Tubes, Material:

    • Economizer + Superheater (ea.): 384 Tubes (ø51 x 5 mm.Thk.) / Mat.: P-265 GH
  • Date of manufacture: 2013
  • Customer, Installed at: AIT/ OCP /Morocco
calderas caldereria industrial
calderas caldereria industrial
calderas caldereria industrial

Heat Recovery Boiler. Baja California Sur IV

  • Type: Heat Recovery Boiler / Superheater + Vaporizer + Economizer
  • Arrangement: Vertical
  • Design data:

    • Superheater: Design pressure: 10 Kg/cm2 / Design temperature: 300° C
    • Vaporizer: Design pressure: 10 Kg/cm2 / Design temperature: 225° C
    • Economizer: Design pressure: 10 Kg/cm2 / Design temperature: 225° C
  • No. of Tubes, Dimensions, Material:

    • Superheater: 216 Tubes (27x8N) (ø51 x 4 mm thk.) / Mat.: A-192
    • Vaporizer: 729 Tubes (27x27N) (ø44.5 x 3.2 mm thk.) / Mat.: A-192
    • Economizer: 162 Tubes (ø44.5 x 3.2 mm thk.) / Mat.: A-192
  • Date of manufacture: 2012/2013
  • Customer, Installed at: Aitesa/Abener /Baja California Sur IV (USA)

Water Heater Coil / Economizer

  • Type: Recovery Boiler / Water Heater + Economizer
  • Arrangement: Vertical
  • Design data:
    • Water Heater: Design pressure: 22.65 Kg/cm2 / Design temperature: 371° C Economizer: Design pressure: 90.6 Kg/cm2 / Design temperature: 371° C
  • No. of Tubes, Dimensions, Material:

    • Water Heater: 240 Tubes (ø38 x 3.6 mm thk. x 13800 mm long) / Mat.: A-192 Economizer: 48 Tubes (ø50.8 x 3.6 mm thk.) / Mat.: A-192
  • Date of manufacture: 2011/2012
  • Customer, Installed at: Cepsa/Tenerife Refinery
calderas caldereria industrial
calderas caldereria industrial
calderas caldereria industrial
calderas caldereria industrial
calderas caldereria industrial

Recovery Boiler. Cepsa Chemicals

  • Type: Heat Recovery Boiler / Vaporizer + Economizer
  • Arrangement: Vertical / Vaporizer (12 x 16N) + Economizer ( 12 x 8N)
  • Design data:
    • Vaporizer: Design pressure: 31Kg/cm2 / Design temperature: 250° C
    • Economizer: Design pressure: 37Kg/cm2 / Design temperature: 250° C
  • Nº of Tubes, Dimensions, Material:: 85(ø6″ Sch.40) /Mat.: A-106Gr.B
  • Date of manufacture: 2011
  • Customer, Installed at: Aitesa / Cepsa / Gibraltar-San Roque Refinery / Cádiz-Spain

Recovery Boiler. Caila & Pares Project

  • Type: Heat Recovery Boiler / Cogeneration Unit / Vaporiser
  • Arrangement: Vertical (36x10N)
  • Design data:
    • design pressure: 16Kg/cm2/ design temperature: 225°C
  • Nº of Tubes, Dimensions, Material:
    • 104(ø2” Sch.40) / Mat.:A-106Gr.B
  • Date of manufacture: 2010
  • Customer, Installed at:
    • Aitesa / Caila & Pares / Barcelona (Spain)
calderas caldereria industrial
calderas caldereria industrial
calderas caldereria industrial

Superheater. F101

  • Tipo: Superheater
  • Arrangement: Horizontal (27x18N)
  • Design data:
    • design pressure: 66,7Kg/cm2/ design temperature: 560°C
  • Nº of Tubes, Dimensions, Material:
    • 486 Tubes(ø60,3 x 5mm.Thk.) / Mat.: A-335 Gr.P91
  • Date of manufacture: 2010
  • Customer, Installed at:
    • AIT / OCP / Morocco

Recovery Boiler. Aralar Paper

  • Type: Heat Recovery Boiler / Cogeneration Unit
  • Arrangement: Vertical / 3 modules / superheater(24x8N)/ Vaporiser (24x12N)/ LP Economiser (36x6N) + LP Vaporizer (36×7+1N) + LP Economiser (36x7N)
  • Design data:
    • Superheater: Design pressure: 39.8 Kg/cm2/ Design temperature: 505° C. HP Vaporiser: Design pressure: 48 Kg/cm2/ Design temperature: 260° C. HP
    • Economiser: Design pressure: 48 Kg/cm2 Design temperature: 260° C. HP Vaporiser: Design pressure: 12 Kg/cm2 Design temperature: 180° C. LP/HP
    • Economiser: Design pressure: 48Kg/cm2 Design temperature: 180° C
  • Nº of Tubes, Dimensions, Material:
    • Superheater: 216 (ø25,4 x 2,4mm.Thk.) Mat.: A-192 / HP Vaporizer.: 288(ø25,4 x 2,4mm.Thk.) Mat.: A-192 / Economizador B.P/A.P..: 252(ø25,4 x 2,4mm.Thk.) Mat.: A-192 / LP / HP Economizer: 252 (ø25.4 x 2.4 mm thk.) Mat.: A-192
  • Date of manufacture: 2010
  • Customer, Installed at: Aitesa / Aralar Paper /Guipúzcoa (Spain)
calderas caldereria industrial
calderas caldereria industrial
calderas caldereria industrial
calderas caldereria industrial
calderas caldereria industrial
calderas caldereria industrial
calderas caldereria industrial
calderas caldereria industrial
calderas caldereria industrial

Unit FCC Recovery Boiler

  • Type: Heat Recovery Boiler
  • Arrangement:
    • Vertical: Total height: 22m Superheater: 34x14N (1 module). Vaporizer: 90x34N (5 modules). Economiser: 36x18N
  • Design data:
    • Superheater: Design pressure: 52.1 Kg/cm2/ Design temperature: 495° C Vaporiser: Design pressure: 55.2 Kg/cm2/ Design temperature: 495° C
    • Economiser: Design pressure: 53.9 Kg/cm2 Design temperature: 276° C
  • Nº of Tubes, Dimensions, Material: Superheater: 476 (ø48.3×5 thk.) Mat.: A-213T22 Vaporiser: 3060 (ø51×5 thk.) Mat. A-192 Economiser: 648 (ø51×5 thk.) Mat.: A-192
  • Date of manufacture: 2009
  • Customer, Installed at: Aitesa/Cepsa/FCC Unit/Refinery Gibraltar-San Roque (Cádiz)

Recovery Boiler. Caracol / Knits / Honduras Project

  • Type: Heat Recovery Boiler.
  • Arrangement: Vertical – Total height: 4.5m. (3 modules)
  • Design data:
    • Design pressure: 11,5 Kg/cm2
    • Design temperature: 200 °C
  • Nº of Tubes, Dimensions, Material:
    • 576(ø44, 5×3, 2Tkh.) Mat.: A-192
  • Date of manufacture: 2009
  • Customer, Installed at: Aitesa/Ingemas (Knoghts/Honduras)